Please follow the architectural plans provided by the project manager or client.
Reception
| Minimum Dimensions | 3.2m x 3m |
| Minimum Ceiling Height | Regulation Ceiling Height |
GM Area
| Minimum Dimensions | 2m x 2m |
| Minimum Ceiling Height | 2.6m |
Briefing Area
| Minimum Dimensions | 3.2m x 3m |
| Minimum Ceiling Height | Regulation Ceiling Height |
Equipment Area
| Minimum Dimensions | 3.2m x 3m |
| Minimum Ceiling Height | Regulation Ceiling Height |
Game Space
| Minimum Dimensions | Rectangle: 16m x 8m Square: 12m x 12m with 80cm pillar in the centre |
| Maximum Dimensions | Rectangle: 20m x 10m Square: 15m x 15m with 1m pillar in the centre |
| Minimum Ceiling Height | 2.6m |
Info
Please confirm with the project manager or client about the exact Game Space size.
Server Area
| Minimum Dimensions | 1.6m x 0.6m |
| Minimum Ceiling Height | Regulation Ceiling Height |
Info
The network equipment should be kept in a consistent ambient temperature of 24 degrees Celsius.
Information for Electricians
Info
Please follow the architectural plans provided by the project manager or client.
Reception
| Number of Power Outlets | 4 |
| Number of Network Points | 1 |
GM Area
| Number of Power Outlets | 8 |
| Number of Network Points | 2 |
Briefing Area
| Number of Power Outlets | 2 |
| Number of Network Points | 1 |
Equipment Area
| Number of Power Outlets | 10 |
| Number of Network Points | 0 |
Info
There can be multiple equipment areas at a venue.
Game Space
| Number of Power Outlets | 0 |
| Number of Network Points | 4 |
Server Area
| Number of Power Outlets | 13 |
| Number of Network Points | (Patch Panel) |
Information for IT Technicians
Internet, Cabling & Wifi Requirements
Minimum 100Mb/s Download and 40Mb/s Upload
UTP CAT 6 Cable Type
- All the network points are to be terminated from the patch panel in the server rack located in the Game Master area to other areas in the venue.
- Each area should be terminated with female CAT6 RJ45 connectors.
2.4Ghz, 5Ghz and 6Ghz
- The Game Space must have less than -60dBm of wireless background Signal to Noise Ratio.
Information for Vinyl Installers
Wall Graphics
| Mandatory | Quantity | Graphic File Size | Recommendation | Links |
| Yes | Enough to cover the perimeter of the Game Space | 20m x 10m or 15m x 15m (cut as required to fit your Game Space) | Printed Mesh or Vinyl Matte | Click here to view the Wall Graphics |
Floor Graphics
| Mandatory | Quantity | Graphic File Size | Recommendation | Links |
| Yes | Enough to cover the Game Space floor | 1.8m x 69m (cut as required for your Game Space) | Vinyl Non-Slip Matte | Click here to view the Floor Graphics |
Info
- It is very important that the graphics are not scaled or stretched in any way. The graphics can be cropped if need be.
- The graphics need to be printed on a non-reflective surface to prevent any tracking issues.
- It is not a big problem if the colours are a little off.